煤气发生炉的专业生产厂家,提供多种煤气发生炉结构图,用煤标准及价格
 
 
  gas generator
 
  Single stage gas generator
 
  Two-stage gas generator
 
  Coal-to-gas furnace for mixing station
 
  Biomass gasifier
 
  LZD type electrostatic purification and recovery device
 
  SF type water film desulfurization dust collector
 
 
 
 
News
当前位置:首页 > News Center > News >
 

Emergency handling of single-stage gas generator

1. When there is a power outage. 
2. When the gas or water supply is stopped for more than 4 hours. 
3. When the single-stage gas generator skirt is burned through and the air supply from the bottom of the furnace overflows from the ash tray and cannot be handled. 
4. When the water jacket of the single-stage gas generator breaks or becomes welded, and it cannot be repaired immediately during operation. 
5. There is a problem with the feeding facilities, manual feeding cannot be achieved, and the gas furnace outlet temperature reaches above 600°C. 
6. When a serious failure occurs in the gas pipeline or dust collector and cannot be dealt with.
 
The above situation is quite serious, and the furnace should be shut down immediately or changed to hot standby. I hope everyone will pay attention to the above items when operating the gas generator!